⚡ Net Metering Bill Calculator
Your bill never leaves your device — the numbers are read inside your browser. Nothing is uploaded to any server.
If your bill has a QR code printed on it, we scan that too — the charges and FPA written inside the QR code are exact, so the calculation comes out right.
We filled these numbers from your bill — please check them, fix any that look wrong, then press Calculate.
Copy the numbers from your latest net metering bill and press Calculate — your net units, unit bank, this month’s bill and the payable or credit (CR) total appear here.
A net metering bill, translated into plain words
A net metering bill is the hardest electricity bill in Pakistan to read. Import and export sit in separate registers, peak and off-peak never cancel each other, surplus units disappear into a unit bank the bill barely explains, and the total can come out as a credit (CR) that looks like a mistake. Most solar owners simply cannot tell whether their bill is right.
This calculator rebuilds the bill the way your DISCO builds it — under the legacy net metering rules that still govern agreements signed before February 2026. Copy the numbers off your latest bill and it shows your net units, your new unit bank, this month’s charges with GST and FPA, and the one line that matters: payable, or credit in your favour. Every figure in the worked example below is produced by this calculator itself.
If you have solar panels and a green meter, your monthly bill is not really a bill — it is a small ledger: units in, units out, a bank that grows and shrinks, and a settlement every third month. This page translates that ledger. Enter the figures from your bill above, and the calculator shows what your DISCO’s arithmetic is doing — and whether the total it printed is the total the rules produce.
Get your bill first — 4 steps
Most people do not keep their bill PDF. You do not need an account or a password to fetch it — only the 14-digit reference number printed on any old bill.
- Go to bill.pitc.com.pk and open the Bill menu at the top. Select your electricity company — LESCO, IESCO, MEPCO, FESCO, GEPCO, HESCO, PESCO, SEPCO, QESCO or TESCO.
- On your company’s bill page, type your 14-digit reference number. In the small dropdown beside the field, select U — that is the net metering option. Enter the CAPTCHA code shown in the image and press Search — your current bill opens on screen.
- Save the bill as a PDF. If you do not know how: click Print at the top right of the page (or right-click and choose Print), then save — the PDF lands in your Downloads folder.
- Come back here and upload that PDF — or upload a complete screenshot of the bill that is properly visible — or simply type the readings into the calculator yourself. Then press Calculate, and your bill is explained: net units, new bank, and payable or credit (CR).
How to read your net metering bill
Five checks, in the order the bill itself is built:
- Find the meter table. Rows marked IMP (import) and EXP (export), each split into peak and off-peak. The units column is this month’s import and export.
- Check the net lines. Off-peak import minus off-peak export; peak stands alone. A negative off-peak net is not an error — it is surplus going into your bank.
- Read the ‘Remaining kWh’ table. That is your unit bank: (O) for off-peak, (P) for peak. A negative peak figure is a shortfall carried forward, not a fine.
- Follow the money stack. Electricity charges, then taxes (GST), then FPA give this month’s bill; your previous credit — shown as a negative arrears figure — is subtracted to reach the grand total.
- Read the grand total. A figure followed by CR means the DISCO owes you. ‘NOT TO BE PAID’ on such a bill means exactly what it says.
The one rule that explains every net metering bill
Peak and off-peak are two separate purses, and units never move between them. Solar panels generate in daylight, which the tariff counts as off-peak — so every unit you export lands in the off-peak purse. Your evening load, when the sun is down and the air conditioners are running, lands in the peak purse.
That is why a household can export far more than it imports and still receive a bill. The off-peak surplus cannot touch the peak units; it can only grow the off-peak bank. On the November 2026 MEPCO bill this calculator was checked against, the household exported 983 units against 234 imported off-peak — a surplus of 749 — yet still had 70 peak units and a month’s bill of Rs 1,991, because peak stands alone.
Once you see the two purses, every line of the bill falls into place: a net line per purse, a bank per purse, and a settlement that finally converts each purse into rupees.
The unit bank and the three-month settlement
Surplus and shortfall both ride in the unit bank from month to month. An off-peak surplus is added to the off-peak bank and drawn down in any later month when imports exceed exports; the peak bank works the same way in reverse, and it is allowed to go negative — a peak shortfall simply accumulates. The bill prints both banks as ‘Remaining kWh’, next to a month count that runs 1/3, 2/3, 3/3.
In the third month the bank is settled in rupees — but not at the tariff you pay for electricity. The two banks are first netted against each other, and the DISCO does not pay you the retail tariff for what is left: your net saved units are converted at NEPRA’s notified power purchase price for net metering — Rs 25.32 per unit for April–June 2026 (S.R.O. 1501(I)/2026). That settlement rate is revised every quarter; it has stayed around Rs 26–27 per unit in recent quarters, always far below the tariff charged for imported units. After month 3 of 3, your saved units are multiplied by the settlement rate (Rs 25.32) and converted into rupees. The DISCO nets your two banks and converts the net saved units at this single notified price — your month-3 bill is the final word for your connection. The banks then restart from zero. Between settlements there is no energy charge at all on banked units, which is why a mid-cycle bill can consist only of fixed charges, FPA and GST.
A peak bank of −274 units, for example, is not a penalty and not a billing error. It is 274 peak units waiting for the settlement month, when they will be netted against your off-peak bank before the remainder is converted at the settlement rate — unless later peak exports cancel them first.
Worked example: one month, end to end
These are the calculator’s preset numbers: a household that imported 300 off-peak and 80 peak units, exported 800 off-peak units, and started the month with 400 units in its off-peak bank, a peak bank 150 units short, and Rs 25,000 of credit.
| Line | Figure |
|---|---|
| Net off-peak units (300 − 800) | −500 — surplus |
| Net peak units | +80 |
| Unit bank — off-peak | 900 units |
| Unit bank — peak | −230 units |
| Fixed & other charges | Rs 1,500 |
| FPA | Rs 450 |
| GST (18% of fixed charges) | Rs 270 |
| This month’s bill | Rs 2,220 |
| Previous credit | Rs 25,000 |
| Grand total | Rs 22,780 CR |
Run the same month as month 3 and the settlement lands instead: the two banks are netted — 900 off-peak units saved against the 230-unit peak shortfall leaves 670 net units — and those convert at the settlement rate of Rs 25.32 per unit, a settlement credit of Rs 16,964. The grand total becomes Rs 39,744 CR, with both banks reset to zero.
Net metering or net billing — which one are you on?
From 9 February 2026, NEPRA’s Prosumer Regulations 2026 (S.R.O. 251(I)/2026) replaced net metering with net billing for new applicants: imports are billed at the full tariff and exports are credited separately at the national average energy purchase price (Rs 8.13 per unit for 2026). Nothing is banked unit-for-unit, and there are no peak and off-peak purses.
Agreements signed before the change keep the legacy rules until their licence expires — the MEPCO bill this page was checked against carries a licence expiry of March 2032. If your bill shows IMP/EXP registers, a Remaining kWh bank and a month count like 2/3, you are on legacy net metering and this calculator follows your rules. If your bill credits exports in rupees at a low flat rate with no bank, you are on net billing — the Solar Calculator covers that system’s maths.
Where each number sits on your bill
| Calculator field | Where it is printed |
|---|---|
| Import and export units | The meter table — IMP and EXP rows, units column, peak and off-peak rows |
| Unit bank | ‘Remaining kWh’ table — (O) is off-peak, (P) is peak; enter the ‘Previous’ column (last month’s closing bank) |
| Credit (CR) | The ‘Arrears’ line — a negative figure is credit in your favour; enter it here as a positive number |
| Fixed & other charges | ‘Total Electricity Charges’ — in a month when both nets ride in the bank, this whole line is fixed and other charges |
| FPA | The ‘Total FPA’ line in the charges breakdown |
| Settlement month | ‘Month Count’ beside the Remaining kWh table (1/3, 2/3 or 3/3) |
Sources. NEPRA Net Metering Regulations 2015 (legacy agreements); NEPRA S.R.O. 1501(I)/2026 (net metering settlement rate Rs 25.32 per unit, April–June 2026); Prosumer Regulations 2026, S.R.O. 251(I)/2026 (net billing; NAEPP Rs 8.13 for 2026). Bill structure and arithmetic checked against a MEPCO net metering bill, November 2026. All DISCOs bill on the same national tariff; if your bill’s stack differs, change the rate and charge fields — the moment you type, the calculator works from your numbers, not its presets.
Frequently asked questions
Why do I still get a bill when I export more units than I import?
Because peak and off-peak never cancel each other. Your exports are off-peak units; your evening peak units stand alone, and fixed charges, FPA and GST are charged every month regardless. A surplus month can still produce a bill — what matters is whether the grand total comes out payable or as credit (CR) after your carried credit is subtracted.
What is the unit bank on a net metering bill?
It is the running balance of units, kept separately for off-peak (O) and peak (P) and printed as ‘Remaining kWh’. An off-peak surplus month adds to the bank; a deficit month draws from it. A negative peak figure is a shortfall carried forward to the settlement month — not a fine and not an error.
What happens at the three-month settlement?
In the third month of the cycle (month count 3/3), the bank is settled in rupees. The DISCO does not pay you the retail tariff for saved units: the two banks are netted, and your net saved units are converted at NEPRA’s notified power purchase price for net metering — Rs 25.32 per unit for April–June 2026 (S.R.O. 1501(I)/2026). The rate is revised every quarter and has stayed around Rs 26–27 per unit in recent quarters, always far below the tariff charged for imported units. After month 3 of 3, your saved units are multiplied by the settlement rate (Rs 25.32) and converted into rupees, both banks restart from zero, and the settlement amount flows into that month’s bill.
Can my exported units cancel my peak units?
No. Under the legacy net metering rules, exported units are off-peak energy and can only offset off-peak imports. Peak imports are settled only by peak exports or, failing those, netted against your off-peak bank and converted at the settlement rate in the settlement month.
What does CR mean on my bill?
CR means credit: the DISCO owes you money, not the other way round. When the grand total is a credit, the bill is marked ‘NOT TO BE PAID’ and the credit carries into next month, where it absorbs that month’s charges before anything becomes payable.
Is net metering still available for a new solar connection?
No. NEPRA’s Prosumer Regulations 2026 replaced net metering with net billing for new applicants from 9 February 2026 — exports are credited in rupees at the national average energy purchase price (Rs 8.13 per unit for 2026) instead of being banked as units. This calculator serves existing net metering agreements, which continue under the legacy rules until their licence expires.
Which numbers do I need from my bill to use this calculator?
Six figures: this month’s import and export units (peak and off-peak), last month’s closing unit bank, the credit (CR) carried on your bill, and the fixed charges and FPA lines from the charges breakdown. The ‘Where each number sits’ table below shows exactly where each one is printed. Rates are preset to the current national tariff and can be changed if your bill shows different ones.